Ceiling Tile & Grid Calculator

Suspended Ceiling Calculator

Calculate ceiling tiles, main tees, 1200mm and 600mm cross tees, wall angle and hangers for a UK suspended ceiling. Enter your room size for a full grid layout with balanced border tiles, or just the area for a quick estimate.

Last reviewed 9 November 2026
Real Grid Layout
600×600 & 1200×600
Hangers & Wall Angle
2026 UK Pricing
Rule of thumb: per m² of a 600 × 600 grid, allow about 2.8 tiles, 0.23 main tees, 1.4 × 1200mm and 1.4 × 600mm cross tees — then add the cut border pieces, which is where most estimates fall short.
Ceiling Details
Enter your room size and choose your tiles
m
m

Square-edge mineral fibre. The everyday office and commercial tile.

5% covers damaged pieces on a simple rectangular room — cuts are already counted in the layout.

mm

Soffit to the underside of the grid. Used for hanger wire length only.

Suspended Ceiling Estimate
Fill in the details, then press Calculate
Ceiling area
—
Tiles
—
tiles to order
Main tees
—
3600mm lengths
Est. total
—
materials

Installation Guide

How a Suspended Ceiling Grid Goes Together

A suspended ceiling is a simple kit — wall angle round the edge, main tees hung on wires, cross tees clipped between them and tiles dropped in. Most ordering mistakes come from forgetting the cut pieces at the walls.

Materials by Room Size (600 × 600 Grid)
Balanced layout with cut borders counted, plus 5% wastage
Room Tiles Main tees 1200 / 600 tees Wall angle
3 × 4m (12 m²) 37 3 19 / 15 5 × 3m
5 × 6m (30 m²) 95 8 48 / 42 8 × 3m
10 × 10m (100 m²) 304 25 152 / 143 14 × 3m
Mains at 1200mm centres running parallel to the longer wall. Cut border tiles are counted as whole tiles, so smaller rooms need proportionally more tiles per m².

1. Set Out the Grid Before You Fix Anything

Find the centre of the room in both directions and plan the grid from there so the border tiles at opposite walls are equal and at least half a tile wide. Decide which way the mains run — usually parallel to the longer wall, and at right angles to the joists or purlins if you are hanging from timber or steel. Mark the main tee lines on the soffit before drilling for hangers.

2. Wall Angle and Hangers

Use a laser level to mark the ceiling height round the walls and fix the wall angle at about 450mm centres, mitring or overlapping the corners. Fix hangers along each main tee line at no more than 1200mm centres, with the first within about 450mm of the wall, and leave the wires long enough to twist off after levelling.

3. Mains, Cross Tees and Tiles

Cut the first main tee so a cross-tee slot lands on your border line, hang it, then join further lengths end to end. Level each main using the hanger wires. Clip the 1200mm cross tees between mains at 600mm centres, then the 600mm cross tees across the middle of each bay for a 600 × 600 grid.

Check the grid is square by measuring the diagonals of a few bays before dropping tiles in. Fit full tiles first and cut the border tiles last, face up with a sharp knife, so any fittings or services above can still be adjusted.

Common Questions

Suspended Ceiling FAQs

Divide the ceiling area by the tile area — 0.36 m² for a 600 × 600mm tile or 0.72 m² for 1200 × 600mm — then allow for cut border tiles. Every cut tile at the wall still uses a whole tile, so a real room needs noticeably more than the area alone suggests: a 10m × 10m ceiling is 278 tiles by area but 289 once the border cuts are counted. Add 5% on top for breakages.
Main tees (also called main runners) are the 3600mm load-bearing sections that hang from the soffit on wires, usually at 1200mm centres. Cross tees clip between them: 1200mm cross tees run at right angles to the mains at 600mm centres, creating a 1200 × 600mm grid. For 600 × 600mm tiles, 600mm cross tees are then clipped across the middle of each 1200 × 600 bay.
For a standard 600 × 600mm grid with mains at 1200mm centres, allow roughly 0.23 main tees (3600mm), 1.39 × 1200mm cross tees and 1.39 × 600mm cross tees per m² of ceiling, plus about 2.8 tiles per m². For 1200 × 600mm tiles, leave out the 600mm cross tees and allow 1.39 tiles per m². These ratios don't include cut border pieces, so add 10% if you are working from area alone.
Hangers are normally fixed along each main tee at no more than 1200mm centres, with one within about 450mm of each end of a run. Extra hangers are needed close to heavy light fittings, air-conditioning cassettes and anywhere a main tee is cut. Always follow the grid manufacturer's spacing for the load and check that the anchors suit the structure you are fixing into.
Most grid systems need a void of at least 100–150mm between the soffit and the underside of the grid, so the tiles can be tilted up and dropped into place. Allow more if recessed lights, ductwork or other services need to run in the void — recessed LED panels typically need 50–100mm of clearance above the grid.
600 × 600mm is the UK standard for offices, schools and retail and suits most recessed LED panels and grilles. 1200 × 600mm tiles need fewer pieces of grid (no 600mm cross tees) and are quicker to install over large areas, but the bigger tiles are more prone to sagging in humid rooms and offer fewer options for lights and access.
Centre the grid in the room rather than starting with a full tile against one wall. Work out the leftover space in each direction, add one full tile width and split it between the two walls — this keeps every border tile at least half a tile wide. The calculator does this automatically when you enter length and width, and shows the border sizes it has assumed.
Wall angle (or perimeter trim) is the L-shaped section fixed level round the walls that supports the edges of the grid and the border tiles. It usually comes in 3000mm lengths and is fixed with plugs and screws at around 450mm centres. Allow the full room perimeter plus wastage for cuts and corners.
Tiles
—
Main Tees
—
Cross Tees
—