Rule of thumb: To reach 0.30 W/m²K on a solid brick wall you need about 110mm of white EPS, 90mm of graphite EPS or 60mm of phenolic. Allow roughly 11 kg/m² of adhesive and basecoat, 6 fixings per m² and 2.5 kg/m² of 1.5mm silicone render.
Walls & System
Thin-coat EWI render systems on houses under 11m

Typical pre-1930s solid brick, U ≈ 2.1 W/m²K. A vapour-open system (mineral wool or wood fibre) is lower risk on older solid walls.

Over existing render, fixings need to be ~20mm longer. Hollow or loose render must be removed first.

The standard when upgrading an existing wall in England and Wales (Approved Document L, renovation of a thermal element).

Pick a size to check a quote — the result shows whether it meets your target.

m
m

Add up every elevation being insulated (e.g. front + side + rear of a semi). Measure height from the DPC to the eaves.

m²

Gable triangles: width × rise ÷ 2

no.

Detached 4 · semi 2 · mid-terrace 0

no.

Standard door: 0.9×2.0m

no.

Standard window: 1.2×1.0m

EWI Specification
Fill in the details, then press Calculate
Net wall
—
Thickness
—
mm insulation
U-Value
—
W/m²K achieved
Wall moves out
—
mm build-up
Choose the wall, target and system, enter the wall size and openings, then press Calculate. Results then update as you change options.

On a 225mm solid brick wall (U ≈ 2.1 W/m²K), 110mm of white EPS reaches 0.30 W/m²K — a 7× reduction in wall heat loss.

EWI Thickness by Insulation Type (Solid Brick Wall)

Calculated from declared λ values · rounded up to stock thicknesses · Approved Document L targets
Insulation λ (W/mK) For 0.30 For 0.21 Combustible?
White EPS700.038110mm180mmYes
Graphite EPS0.03190mm140mmYes
Mineral wool slab0.036110mm160mmNo (A1)
Wood fibre0.043130mm200mmYes
Phenolic0.02160mm90mmYes
Thickness = (1/Utarget − 1/Uexisting) × λ. Check the declared λ of the exact product — graphite EPS ranges 0.030–0.032 and mineral wool slabs 0.035–0.040.

Thin-Coat EWI Material Rates per m²

Typical BBA system figures used by this calculator — your system's datasheet takes precedence
Layer Rate Pack
Board adhesive~5 kg/m²25kg bag ≈ 5 m²
Basecoat (5–6mm)~6 kg/m²25kg bag ≈ 4 m²
Reinforcing mesh1.1 m²/m²50m² roll (100mm laps)
Mechanical fixings6–8 /m²Boxes of 100–200
Primer~0.25 kg/m²20kg tub ≈ 80 m²
Silicone render 1.5mm~2.5 kg/m²25kg tub ≈ 10 m²
Silicone render 2.0mm~3.0 kg/m²25kg tub ≈ 8 m²

EWI Guide

How External Wall Insulation Works

The thin-coat EWI build-up

A thin-coat EWI system is a set of layers sold and certified together (BBA or ETA). From the wall outwards: a starter track fixed above the DPC, insulation boards bonded with adhesive and pinned with mechanical fixings, a basecoat with fibreglass mesh embedded in it, a primer, and a tinted topcoat render 1–3mm thick.

Corners get mesh corner beads, window heads get drip beads, and window frames get a connection (APU) bead so the render seals to the frame. Mixing components from different systems usually voids the system guarantee, so buy the whole system from one manufacturer.

Worked example — three-bed semi

A solid brick semi insulated on the front, side and rear: 21m of wall at a 5.2m eaves height, plus a 10m² side gable, with 1 door and 8 windows. That gives 119.2m² gross, less 11.4m² of openings, so 107.8m² net.

To reach 0.30 W/m²K: (1/0.30 − 1/2.1) × 0.038 = 0.109m, so 110mm white EPS, achieving ~0.297 W/m²K. With 10% wastage, that's 165 boards, 24 bags of adhesive, 30 bags of basecoat, 3 rolls of mesh, about 750 fixings at 160mm and 13 tubs of 1.5mm silicone render. The materials come to roughly £2,400–£5,700 inc. VAT — about £34/m² at mid-market prices.

What EWI costs installed

The Federation of Master Builders puts installed EWI at £85–£130 per m², or around £10,000 for a typical three-bedroom semi (March 2026). Materials are usually a third or less of that. The rest is scaffolding, labour, and the detailing at windows, eaves, pipes and meters that a materials list doesn't capture.

When comparing quotes, check they name the system and board thickness, include the reveals, sills and eaves work, and come with an insurance-backed guarantee.

Building Regulations, planning and VAT

Building Regs: insulating more than 50% of a wall counts as renovating a thermal element under Approved Document L. The wall should reach 0.30 W/m²K where technically and economically feasible. Competent-person-scheme installers can self-certify; otherwise, apply to building control.

Planning: EWI on a house in England is often permitted development where the finish is similar in appearance to the existing walls. Rendering over brick, conservation areas, listed buildings and Article 4 areas usually need consent.

VAT: supply-and-fit insulation is zero-rated in Great Britain until 31 March 2027. Materials bought for DIY carry 20% VAT.

Choosing between EPS, mineral wool and wood fibre

White EPS is the cheapest and lightest, and the default on most houses. Graphite EPS costs a little more but is about 20% thinner, which helps where eaves or window positions limit the build-up.

Mineral wool is non-combustible and vapour-open — the safer choice on older solid walls and near boundaries. Wood fibre is also vapour-open and suits heritage properties, but it is the thickest and most expensive. Phenolic is the thinnest of all but is not vapour-open.

FAQ

Common Questions

To meet the 0.30 W/m²K renovation standard on a 225mm solid brick wall you typically need about 110mm of white EPS, 90mm of graphite EPS, 110mm of mineral wool or 60mm of phenolic board. Thinner walls, stone or cavity walls change the figure slightly, which is why the calculator works it out from your wall type.

Installed EWI typically costs £85–£130 per m² in the UK (Federation of Master Builders, March 2026), or around £10,000 for a typical three-bedroom semi. Materials alone for a thin-coat EPS and silicone render system usually run around £25–£40 per m², depending on the board and finish.

Silicone render is the most popular EWI finish in the UK because it is water-repellent, flexible and largely self-cleaning. Silicone-silicate is more vapour-open, so it pairs better with mineral wool or wood fibre on older solid walls. Acrylic is cheaper but picks up dirt more readily, and mineral render is very breathable but usually needs painting.

EPS is cheaper, lighter and easier to install, and is the usual choice on houses. Mineral wool is non-combustible (Class A1) and vapour-open, so it is preferred on older solid walls, near boundaries and on taller buildings, where combustible insulation is restricted under Approved Document B. Graphite EPS sits between them on cost and is around 20% thinner than white EPS for the same U-value.

In England, EWI on a house is often permitted development when the finished appearance is similar to the existing walls. Changing a brick house to render, or any EWI in a conservation area, on a listed building or where an Article 4 direction applies, usually needs planning permission. Check with your local planning authority before ordering materials.

Yes, in most cases. Insulating more than 50% of an external wall (or more than 25% of the whole building envelope) counts as renovating a thermal element under Approved Document L, so the wall must be upgraded to 0.30 W/m²K where technically and economically feasible. A registered installer under a competent person scheme can self-certify; otherwise you need a Building Regulations application.

Insulation supplied and installed by a contractor in Great Britain is zero-rated for VAT until 31 March 2027 under the energy-saving materials relief. Materials you buy yourself for a DIY install are standard-rated at 20%. The calculator shows retail material prices, so use the ex-VAT toggle if you are pricing a supply-and-fit job.

It is possible on a simple single-storey wall, but most EWI jobs need scaffolding, careful detailing at windows, eaves and the DPC, and a BBA-certified system installed to the manufacturer's spec to keep the guarantee valid. Grant-funded work must be installed by a TrustMark-registered installer to PAS 2030/2035. For most homeowners the calculator is best used to check quotes.

ECO4 is closing on 31 December 2026 and the Great British Insulation Scheme ended on 31 March 2026. Low-income households in England may be eligible for the Warm Homes: Local Grant through their council, and the Warm Homes Plan is the government's main retrofit funding programme. Wales and Scotland run their own schemes, so check with your council or the relevant national energy advice service.

Thickness
—